Flowkit
K-DenseCommunityCreated by K-Dense Inc.
- Skill
- Tool integration
- Science and research
- MIT
- Low risk
- Has scripts
AutoGineer summary
Written by AutoGineer from the skill’s own files, not by the author
FlowKit is a Python-based tool for processing and analyzing flow cytometry data. It enables users to perform spillover compensation, apply logicle and biexponential transforms, and execute hierarchical gating strategies. The tool supports GatingML 2.0 and provides compatibility with a subset of FlowJo 10 workspaces, allowing for reproducible analysis of FCS files. It is designed for researchers needing to automate gating, generate population statistics, or validate cytometry results programmatically.
What it does
- Applies spillover compensation to flow cytometry data.
- Executes hierarchical gating strategies using GatingML or FlowJo workspaces.
- Performs logicle and biexponential data transformations.
- Generates reproducible gate counts and population percentage reports.
- Exports analysis results including provenance and population paths.
- Provides a Python API for building custom gating strategies.
When to use it
- When you need to reproduce FlowJo 10 workspace analyses in a Python environment.
- When automating the gating of large batches of FCS files.
- When you require programmatic control over cytometry data processing and compensation.
- When generating standardized reports for scientific studies.
Advantages
- Enables reproducible, scriptable cytometry analysis.
- Supports standard GatingML 2.0 formats for interoperability.
- Provides detailed provenance and reporting for scientific audit trails.
- Allows for custom, complex gating logic beyond standard GUI tools.
Usage examples
- “Analyze a FlowJo workspace study using FlowKit.”
- The tool processes the specified FCS files against the workspace definitions, outputting a gate_report.csv and provenance.json with population statistics.
- “Build a custom gating strategy in Python for FCS data.”
- A GatingStrategy object is created, compensation matrices and transforms are registered, and gates are applied to generate a report and exportable GatingML file.
Install
Download the skill as a ZIP:
https://mp-staging.autogineer.com/agent-skills/k-dense-ai/flowkit/downloadUnzip it into the cross-client skills folder of your project:
mkdir -p .agents/skills && unzip flowkit.zip -d .agents/skills
Documentation by K-Dense Inc.
FlowKit
When to use
Use FlowKit to apply or build cytometry gating strategies, analyze batches of FCS samples, or reproduce supported FlowJo workspace analyses. It supports GatingML 2.0 and a subset of FlowJo 10 features. Import success alone does not establish agreement with FlowJo.
The examples and bundled helper target FlowKit 1.3.2 on Python 3.13. Upstream supports additional Python versions; those were not exercised here. The helper and examples were tested on synthetic FCS data, including a public FlowJo 10.7.1 synthetic workspace fixture. They are not biological validation.
Install
Use a separate environment; FlowKit 1.3.2 requires NumPy >2 and pandas <3:
uv venv --python 3.13 .venv-flowkit
uv pip install --python .venv-flowkit/bin/python "flowkit==1.3.2"
.venv-flowkit/bin/python -c "import flowkit; print(flowkit.__version__)"The scientific package is BSD-3-Clause licensed; this skill is MIT licensed.
Workflow
Identify the analysis definition. Use
Sessionfor a programmatic or GatingML strategy; useWorkspacefor FlowJo sample-specific gates, compensation, and transforms. Request the actual strategy or controls when biological thresholds have not been supplied.Inspect samples and channel identities. Match detector/PnN labels to compensation matrices and gate dimensions; PnS marker names may be empty or repeated. Verify sample IDs: the default is FCS
$FIL, which can differ from the current filename. Reject ID collisions before loading a batch.Establish the coordinate system. Determine whether the supplied events are already compensated. Apply compensation before nonlinear transforms; match gate thresholds to the same transformed or untransformed coordinates. See compensation and gating.
Check the hierarchy. Preserve parent gates and full gate paths, including
root. For a study, review acquisition/time stability, debris exclusion, singlets, viability, and phenotype gates as appropriate to its panel. Use single-stain controls for compensation and suitable negative/FMO controls for positivity; demonstration thresholds are not transferable biology.Analyze and inspect. Run on all events, then check gate overlays and sample-level QC. A plot's subsample is not the population denominator. Review warnings and compare representative imported results to FlowJo.
Export counts with denominators and provenance. Keep gate paths, sample IDs, total event counts, input hashes, package versions, and the analysis definition. Keep biological replicates identifiable; events from one specimen are not independent experimental replicates.
Apply an existing strategy
Set FLOWKIT_SKILL_DIR to this skill's installed directory. From the repository
root it is skills/flowkit. Paths below represent the user's local inputs.
FLOWKIT_SKILL_DIR="skills/flowkit"
uv run --no-project --python 3.13 --with "flowkit==1.3.2" \
python "$FLOWKIT_SKILL_DIR/scripts/analyze_gates.py" \
--gatingml gates.xml --fcs sample.fcs --output-dir results-gatingmlFor a FlowJo workspace, supply every FCS file in the selected group:
uv run --no-project --python 3.13 --with "flowkit==1.3.2" \
python "$FLOWKIT_SKILL_DIR/scripts/analyze_gates.py" \
--workspace study.wsp --group "Study" \
--fcs sample-a.fcs sample-b.fcs --output-dir results-workspaceThe helper writes gate_report.csv and provenance.json to a new directory.
Each row includes sample_event_count, parent_event_count, and a full
population_path; empty-parent percentages are blank and flagged with
relative_percent_defined=False.
It rejects duplicate sample IDs, missing/extra workspace-group samples,
zero-event samples, and strategies without gates. It uses explicit input files,
does not follow paths embedded in the workspace, and runs without
multiprocessing or transformed-event caching. It still loads each sample into
memory; use manageable batches via the Python API for large studies.
--filename-as-id deliberately switches from $FIL to file basenames. Use it
only when those names match the analysis definition. See
workspace analysis for partial-group
analysis, result interpretation, and fluorescence summaries.
Build a strategy in Python
This runnable example uses sample.fcs with FSC-A, FL1-A, and FL2-A.
The matrix, thresholds, and transform parameters are synthetic teaching
values. Replace them with the study's validated settings.
import flowkit as fk
import numpy as np
sample = fk.Sample("sample.fcs")
strategy = fk.GatingStrategy()
strategy.add_comp_matrix(
"spill", fk.Matrix(
np.array([[1.0, 0.1], [0.2, 1.0]]), ["FL1-A", "FL2-A"],
fluorochromes=["FITC", "PE"],
)
)
logicle = fk.transforms.LogicleTransform(
param_t=262144, param_w=0.5, param_m=4.5, param_a=0
)
strategy.add_transform("logicle", logicle)
strategy.add_gate(
fk.gates.RectangleGate("Cells", [
fk.Dimension("FSC-A", range_min=50, range_max=300)
]),
gate_path=("root",),
)
thresholds = logicle.apply(np.array([50.0, 600.0]))
strategy.add_gate(
fk.gates.RectangleGate("Positive", [
fk.Dimension(
"FL1-A", compensation_ref="spill", transformation_ref="logicle",
range_min=float(thresholds[0]), range_max=float(thresholds[1]),
)
]),
gate_path=("root", "Cells"),
)
session = fk.Session(gating_strategy=strategy, fcs_samples=[sample])
session.analyze_samples(use_mp=False)
report = session.get_analysis_report()
print(report[["sample_id", "gate_path", "gate_name", "count",
"absolute_percent", "relative_percent"]])
with open("gates.xml", "xb") as handle:
session.export_gml(handle)GatingML exports a template by default. When custom per-sample gates exist,
use session.export_gml(handle, sample_id=sample.id) for that sample's strategy.
A single template export does not preserve every sample-specific override.
Interpretation checks
countis the number of events passing the gate and its ancestors.absolute_percentis percent of all sample events;relative_percentis percent of the immediate parent. These are percentages, not fractions.Gate names can repeat under different parents. In the helper's output use
(sample_id, population_path)as the identifier. Paths are JSON arrays inside CSV cells. FlowKit's native report stores a quadrant's owner separately inquadrant_parent; itsgate_pathalone omits that owner.A zero-event parent makes a child percentage biologically undefined; FlowKit 1.3.2 reports zero for ordinary children and NaN for quadrants. The helper exports both as blank with an explicit false flag. This differs from a defined 0% for an empty gate whose parent contains events.
Compensated negative fluorescence is legitimate. Do not clip it to zero or discard those events merely to permit a logarithmic transform.
Define whether “MFI” means mean or median and name the event source. A transformed display value is not an intensity on the original scale.
References
Compensation and gating: event sources, detector order, transform semantics, gate paths, and plotting.
Workspaces and results: sample matching, missing FCS files, FlowJo limits, and gated fluorescence summaries.
FlowKit API and versioned source: consult signatures when moving beyond the tested release.
FlowKit publication: cite the software and version in scientific methods when used for analysis.
Files
- ATTRIBUTION.mdAdded by AutoGineer907 B
- LICENSELicence file added by AutoGineer1.0 KiB
- SKILL.md8.5 KiB
- references/compensation-and-gating.md4.8 KiB
- references/workspaces-and-results.md6.4 KiB
- scripts/analyze_gates.pyScript8.6 KiB
references/compensation-and-gating.md
Compensation, transforms, and gates
Event sources are different representations
FlowKit Sample uses FlowIO preprocessing by default: gain, logarithmic FCS
encoding, and time scaling are applied when loading. Consequently,
sample.get_events(source="raw") is before compensation/transforms, not
necessarily the values encoded in the FCS DATA segment. Reserve
preprocess=False for explicitly investigating encoding; it changes the
coordinate system and may make an existing strategy inappropriate.
source="comp" requires compensation to have been applied to the Sample;
source="xform" requires transformation. The default event source is xform,
so specify the source instead of relying on it. Gating a Sample through a
GatingStrategy processes its own event arrays; do not assume that it also
populates the Sample's comp or xform arrays.
Compensation
Construct fk.Matrix(spill_data_or_file, detectors, fluorochromes=None) using
detector/PnN names in the matrix's order. Inputs can be a NumPy matrix, an FCS
spillover keyword string, or supported spillover text. Marker/PnS labels are
annotations and do not replace detector identity. Confirm that all detectors
are present, the matrix is finite and nonsingular, and the fluorescence panel
matches the controls. An identity matrix means no cross-channel spillover; it
is not a fallback for a missing matrix.
For GatingML export in 1.3.2, supply nonempty fluorochromes labels as well.
Omitting them leaves empty labels in the exported XML, which fails GatingML
schema validation on re-import even though in-memory gating works. Use the
panel's actual fluorochrome names in matrix order and verify the round-trip.
For a programmatic strategy, register it with
strategy.add_comp_matrix("spill", matrix) and set
compensation_ref="spill" on the relevant Dimensions. The special reference
"FCS" uses spillover metadata from each sample; check that every sample has
the intended metadata before using it. The default dimension reference is
"uncompensated". Merely registering a matrix does not apply it to all gates.
For direct fluorescence summaries, use sample.apply_compensation(matrix)
and explicitly read source="comp". This starts from that Sample's raw event
array. It cannot detect that the FCS itself was exported already compensated;
verify export provenance to avoid compensating such data a second time.
Classical spillover compensation is not a general replacement for spectral unmixing. Confirm how spectral-instrument data were unmixed and exported.
Transform and threshold coordinates
LogicleTransform(param_t, param_w, param_m, param_a) handles signed
fluorescence. Match parameters to the acquisition and analysis definition;
the values in the quick start are illustrative. FlowJo's
WSPBiexTransform is a distinct transform; substituting logicle or an
arbitrary arcsinh cofactor can change imported gate membership.
Register transforms with strategy.add_transform(id, transform) and reference
that ID on each dimension needing it. Gate vertices/bounds must be in the
coordinates of that dimension. If a scientifically justified threshold is on
the untransformed compensated scale, transform that threshold with the same
object used for the data, as the quick start does. Do not transform imported
workspace gates again; the workspace parser handles their coordinates.
Hierarchy and visual checks
Top-level gates have path ("root",). A child of Cells has path
("root", "Cells"); the gate's own name is excluded from its path. Rectangle
lower bounds are inclusive and upper bounds exclusive. Missing bounds are
unbounded. Polygon boundaries and events near thresholds require particular
care when comparing software implementations.
Get Boolean event masks using
session.get_gate_membership(sample_id, gate_name, gate_path=path). Masks
retain the original sample's event order and cover the entire sample. Their
sum should match the reported count, and child masks should be subsets of
their parents. Boolean/overlapping gates need not sum to the parent count;
mutually exclusive quadrants should be checked as a partition when applicable.
session.plot_gate(sample_id, gate_name, gate_path=path) returns a Bokeh plot.
Save it with bokeh.plotting.save, using bokeh.resources.INLINE when the
HTML must work offline. Inspect events and gate boundaries in matching
coordinates; plotting uses subsampling for large samples, while analysis
uses full event arrays. Plotting is not evidence that controls support a gate.
Primary sources
Requirements and compatibility
Works with: Claude Code, Claude apps, OpenAI Codex, GitHub Copilot, Cursor, Gemini CLI, Kiro, OpenCode, Goose, Amp, Roo Code, JetBrains Junie, Factory Droid, Devin (ex-Windsurf), Mistral Vibe, OpenHands, Letta
“Works with” means the tool reads the open Agent Skills format; a skill written for one tool may use features others lack.
Needs: Needs Python
The author says: Requires Python 3.13 with flowkit==1.3.2 for the tested environment. Dependencies include FlowIO, FlowUtils, NumPy, pandas, SciPy, lxml, and Bokeh. Installation needs network access; analysis uses local FCS/XML/WSP files without credentials. FlowUtils needs a C compiler if a compatible wheel is unavailable.
Security
What our scanner noticed· Low risk
- Instructions that use the network
- Scripts that your agent may run
This skill includes scripts that your agent may run. Read them before you use it.
A static scan is not a guarantee. Skills are third-party content: review a skill before you let an agent use it.
Attribution and licence
- Created by
- K-Dense Inc.
- Publisher
- K-Dense (Community)
- Source
- K-Dense-AI/scientific-agent-skills · skills/flowkit · commit a25cf9e
- Licence
- MIT License (redistribution allowed)
- LICENSE (added by AutoGineer from LICENSE.md)
- ATTRIBUTION.md (written by AutoGineer)
- Synced
AutoGineer is not affiliated with or endorsed by K-Dense Inc. or K-Dense.
Download ZIP
The ZIP holds the skill’s files, its licence files and an ATTRIBUTION.md. Download flowkit.zip