This skill provides a structured approach to using MATLAB Audio Toolbox for acoustic measurement and analysis. It guides users through selecting the correct functions for psychoacoustic metrics, speech intelligibility, noise compliance, and broadcast loudness. The skill emphasizes proper calibration techniques, standard-compliant workflows, and the correct handling of signal data to ensure accurate results, while explicitly warning against the use of nonexistent or licensed-restricted functions.
What it does
- Calculates psychoacoustic metrics like loudness, sharpness, roughness, and fluctuation strength.
- Evaluates speech quality and intelligibility using metrics such as ViSQOL, STOI, STI, and SII.
- Assesses noise compliance using NC, RC, and RNC ratings for various environments.
- Performs offline SPL measurements and broadcast loudness checks (EBU R 128).
- Provides guidance on microphone calibration and system-level calibration factors.
- Offers standard-compliant filtering and unit conversion utilities.
When to use it
- When you need to measure perceived loudness or sound quality in a research or engineering context.
- When evaluating room acoustics or HVAC noise compliance against industry standards.
- When analyzing speech intelligibility for communication systems or public address setups.
- When you need to calibrate audio recordings for accurate SPL or metric computation.
- When you need to perform broadcast loudness compliance checks.
Advantages
- Ensures adherence to international standards like ISO 532-1/2, ANSI/ASA S12.2, and IEC 60268-16.
- Prevents common errors such as incorrect function usage, argument ordering, or manual implementation of complex algorithms.
- Provides clear guidance on calibration to ensure measurement accuracy.
- Streamlines the selection of appropriate metrics based on specific application goals.
Usage examples
- “How do I calculate the loudness of a recording in sones?”
- The agent will guide you to use the acousticLoudness function, specifying the ISO 532-1 method, applying your calibration factor, and selecting the appropriate sound field.
- “Is my office HVAC noise compliant?”
- The agent will recommend using the roomCriteria function to obtain an RC rating, explaining how to interpret the output and verify the measurement conditions.
- “How can I measure the speech quality of a processed audio file?”
- The agent will instruct you to use the visqol function with the 'speech' mode, ensuring the processed signal is passed as the first argument.
- “How do I calibrate my microphone for SPL measurements?”
- The agent will explain how to use calibrateMicrophone with a 1 kHz tone recording and a known SPL reference to compute the correct calibration factor.
Install
Download the skill as a ZIP:
https://mp-staging.autogineer.com/agent-skills/matlab/matlab-evaluate-acoustic-metrics/downloadUnzip it into the cross-client skills folder of your project:
mkdir -p .agents/skills && unzip matlab-evaluate-acoustic-metrics.zip -d .agents/skills
Documentation by MathWorks
Evaluate Acoustic Metrics
Select the correct Audio Toolbox function for acoustic measurement, apply proper calibration, and choose appropriate standards — instead of reimplementing algorithms or calling nonexistent functions.
When to Use
Computing psychoacoustic metrics (loudness, sharpness, roughness, fluctuation)
Evaluating speech quality or intelligibility (ViSQOL, STOI, STI, SII)
Assessing noise compliance (NC rating, RC rating, RNC, SIL)
Measuring SPL from recordings (offline, calibrated)
Computing broadcast loudness (EBU R 128 / LUFS)
Measuring reverberation time (RT60) from impulse responses
Detecting tonal content (tone-to-noise ratio, prominence ratio)
Converting microphone sensitivity to CalibrationFactor
User mentions PESQ or POLQA (redirect to correct alternatives)
When NOT to Use
Real-time streaming audio processing loops — use
matlab-process-streaming-audioAudio device I/O, recording, or live
calibrateMicrophone— usematlab-play-record-audioAudio plugin authoring (VST/AU) — use
matlab-write-audio-pluginGeneral filter design unrelated to measurement — use
matlab-design-digital-filterSpatial audio / HRTF / SOFA processing
Workflow
Follow this decision tree to route the user's goal to the right function:
1. Identify the measurement goal
| Goal | Category | Go to |
|---|---|---|
| "How loud is it?" (perceived) | Psychoacoustic | → Psychoacoustic Metrics |
| "Does it comply with broadcast loudness?" | Broadcast | → Broadcast Loudness |
| "Is the noise level acceptable for this space?" | Noise compliance | → Noise Compliance |
| "Can people understand speech in this room?" | Speech intelligibility | → STI/SII Measurement |
| "How good does processed speech sound?" | Speech quality | → Speech Quality |
| "What's the SPL?" | Level measurement | → SPL Measurement |
| "What's the reverberation time?" | Room acoustics | → RT60 |
| "Is there a tonal component?" | Tonality | → Tonality |
2. Ask before computing
Before writing code, confirm these with the user:
Calibration: Do they have a CalibrationFactor? Did they calibrate with
calibrateMicrophone? (See Calibration section)Standard: Which standard or method applies? (ISO 532-1 vs 532-2, NC vs RC vs RNC)
Sound field: Free field or diffuse field recording?
Application context: What space type? What's the concern? (Drives NC vs RC vs RNC selection)
3. Select function and apply
Use the Key Functions table and the category-specific patterns below.
Functions That Do NOT Exist
| Function | Status | Use Instead |
|---|---|---|
pesq | Does NOT exist (proprietary ITU-T P.862 license) | visqol(degraded, reference, fs, Mode="speech") |
polqa | Does NOT exist (proprietary ITU-T P.863 license) | visqol(degraded, reference, fs) |
Never suggest pesq or polqa. They are not in Audio Toolbox and cannot be added due to licensing.
Key Functions
| Function | Purpose | Standard | Available From |
|---|---|---|---|
acousticLoudness | Perceived loudness (sones) | ISO 532-1/2 | R2020a |
acousticSharpness | Perceived sharpness (acum) | DIN 45692 | R2020a |
acousticRoughness | Perceived roughness (asper) | — | R2021a |
acousticFluctuation | Fluctuation strength (vacil) | — | R2020b |
integratedLoudness | Broadcast loudness (LUFS) | EBU R 128 / ITU-R BS.1770 | R2016b |
loudnessMeter | Streaming broadcast loudness meter | EBU R 128 / ITU-R BS.1770 | R2018a |
visqol | Full-reference audio quality (MOS) | — | R2024a |
stoi | Short-time objective intelligibility | — | R2024a |
mnru | Modulated noise reference unit | ITU-T P.810 | R2024a |
dBov | Power level relative to overload (dB) | ITU-T G.100.1 | R2024a |
speechTransmissionIndex | STI from IR or test signals | IEC 60268-16 | R2026a |
speechIntelligibilityIndex | SII from IR, test signals, or levels | ANSI/ASA S3.5-1997 | R2026b |
stipaExcitation | Generate STI/STIPA test signals | IEC 60268-16 | R2026a |
siiExcitation | Generate SII test signals | ANSI/ASA S3.5-1997 | R2026b |
noiseCriteria | NC rating + SIL + spectrum imbalance + rattle risk | ANSI/ASA S12.2 | R2026b |
roomNoiseCriteria | RNC rating (detects surging/fluctuations) | ANSI/ASA S12.2 | R2026b |
roomCriteria | RC Mark II rating (HVAC systems) | ANSI/ASA S12.2 | R2026b |
noiseCriteriaCurves | Look up NC curve values | ANSI/ASA S12.2 | R2026b |
noiseCriteriaRecommendations | Recommended NC levels by room type | ANSI/ASA S12.2 | R2026b |
speechInterferenceLevel | SIL from recording | ANSI/ASA S12.2 | R2026b |
rt60 | Reverberation time from impulse response | ISO 3382-1/2 | R2025a |
acousticToneToNoiseRatio | Detect/quantify tones | ECMA-418-1 | R2023b |
acousticProminenceRatio | Tonality via critical band comparison | ECMA-418-1 | R2023b |
splMeter | SPL measurement (time-weighted, per-band) | IEC 61672 | R2018a |
calibrateMicrophone | Compute calibration factor from known tone | — | R2018b |
weightingFilter | A/C/Z/K frequency weighting | IEC 61672-1 | R2016b |
octaveFilter | Single octave-band filter | ANSI S1.11-2004 | R2017b |
octaveFilterBank | Multi-band octave filtering | ANSI S1.11-2004 | R2019a |
See references/function-arguments.md for complete argument lists, defaults, and valid values for each function — consult when constructing calls with non-default parameters.
Calibration
CalibrationFactor from microphone sensitivity
Convert dB sensitivity (dBV/Pa) to the linear CalibrationFactor:
sensitivity_dBV = -26; % Example: -26 dBV/Pa microphone
calibrationFactor = 1 / 10^(sensitivity_dBV/20);The CalibrationFactor is the 3rd positional argument for acousticLoudness, acousticSharpness, acousticRoughness, and acousticFluctuation (default: sqrt(8)). For noise compliance functions, pass it as a name-value: CalibrationFactor=value.
System-level calibration advice
Always ask the user about their signal chain. If the recording path includes a preamp, audio interface, or ADC with unknown gain, the mic sensitivity spec alone is insufficient. Recommend:
Play a 1 kHz tone through the system and record it through the full signal chain (mic → preamp → ADC → WAV). Use a pistonphone for a known 94 dB reference, or place a physical SPL meter next to the microphone to get an SPL reading.
Compute the system calibration factor:
calibrationFactor = calibrateMicrophone(calRecording, fs, SPLreading, FrequencyWeighting="Z-weighting")Pass that factor to the measurement function
calibrateMicrophone expects a 1 kHz tone recording as input. The SPLreading argument is the known SPL in dB (e.g., 94 from a pistonphone, or the value shown on a physical SPL meter).
Cross-reference: for the physical recording workflow with calibrateMicrophone, see the matlab-play-record-audio skill.
Patterns
Psychoacoustic Metrics
[audioIn, fs] = audioread("recording.wav");
calFactor = 1 / 10^(-26/20);
loudness = acousticLoudness(audioIn, fs, calFactor, ...
Method="ISO 532-1", SoundField="diffuse", TimeVarying=true);
sharpness = acousticSharpness(audioIn, fs, calFactor, ...
SoundField="diffuse", TimeVarying=true);
roughness = acousticRoughness(audioIn, fs, calFactor, SoundField="diffuse");
fluctuation = acousticFluctuation(audioIn, fs, calFactor, SoundField="diffuse");Return types: acousticLoudness returns a scalar (sones) for stationary analysis. With TimeVarying=true, it returns a column vector (time-varying loudness in sones). The second output (specificLoudness) is a matrix (time x critical bands). It does NOT return a struct or timetable.
Ask the user:
ISO 532-1 (Zwicker, stationary/time-varying) or ISO 532-2 (Moore-Glasberg)?
Free-field or diffuse-field recording?
Time-varying analysis needed?
See references/psychoacoustic-metrics.md for method selection guidance (ISO 532-1 vs 532-2), interpretation tables (sone values, sharpness/roughness/fluctuation scales), tonality metric selection, and combined sound quality assessment workflows.
Unit Conversions
Use built-in functions — do NOT reimplement conversion formulas manually:
| Conversion | Function | Method selection |
|---|---|---|
| phon → sone | phon2sone(phon, standard) | "ISO 532-1" (default), "ISO 532-2" |
| sone → phon | sone2phon(sone, standard) | "ISO 532-1" (default), "ISO 532-2" |
| Hz → ERB | hz2erb(freq) | Single formula (no variants) |
| ERB → Hz | erb2hz(erb) | Single formula (no variants) |
| Hz → bark | hz2bark(freq) | Single formula (no variants) |
| bark → Hz | bark2hz(bark) | Single formula (no variants) |
| Hz → mel | hz2mel(freq, MelStyle=s) | "oshaughnessy" (default), "slaney" |
| mel → Hz | mel2hz(mel, MelStyle=s) | "oshaughnessy" (default), "slaney" |
When the user specifies a standard (e.g., "ISO 532-2"), pass it as the second positional argument for phon2sone/sone2phon. For hz2mel/mel2hz, use the MelStyle name-value pair.
Noise Compliance
Choose the function based on the application:
| Situation | Function | Why |
|---|---|---|
| General background noise rating | noiseCriteria | Standard NC curves (ANSI/ASA S12.2) |
| HVAC system noise specifically | roomCriteria | RC Mark II designed for HVAC evaluation |
| Noise with audible surging/fluctuation | roomNoiseCriteria | RNC penalizes time-varying noise (requires ≥15 s recording) |
| Quick speech interference check | speechInterferenceLevel | Direct SIL value |
| Need recommended levels for room type | noiseCriteriaRecommendations | Lookup table by room use |
[audioIn, fs] = audioread("office_noise.wav");
[NC, SIL, specImbalance, rattleRisk] = noiseCriteria(audioIn, fs, ...
CalibrationFactor=2.3);
[RC, LMF, QAI, rattleRisk] = roomCriteria(audioIn, fs, ...
CalibrationFactor=2.3);
SIL = speechInterferenceLevel(audioIn, fs, CalibrationFactor=2.3);
rec = noiseCriteriaRecommendations("NC", Occupancy="all");Return types:
NCis a string (e.g.,"NC-35"or"NC-56 (1000 Hz)"if a band exceeds)RCis a string (e.g.,"RC-32(N)"— the letter indicates spectrum quality: N/R/H/RV)SILandLMFare double scalars (dB)QAIis a double scalar (dB; 0 = ideal neutral)specImbalanceandrattleRiskare structs with.Summary(string) and.Details(table) — access.Summaryfor display. Exception:specImbalancedegrades to acharscalar (not a struct) when NC exceeds the curve range (e.g., "Above NC-70") or falls below NC-15. Guard withisstruct(specImbalance)before dot-indexing.noiseCriteriaRecommendationsrequires a criteria name argument:"NC","RNC", or"RC"
Ask the user:
What type of space? (office, classroom, hospital, concert hall)
Is the noise source HVAC? → prefer
roomCriteriaIs the noise steady or fluctuating? → if fluctuating, use
roomNoiseCriteria
See references/noise-compliance.md for detailed output interpretation and selection guidance.
Speech Quality
[degraded, fs] = audioread("processed_speech.wav");
[reference, ~] = audioread("reference_speech.wav");
mosScore = visqol(degraded, reference, fs, Mode="speech");
intelligibility = stoi(degraded, reference, fs);Critical: stoi and visqol argument order is (processed, reference, fs) — processed/degraded signal FIRST.
visqol modes: "speech" for narrowband/wideband speech (outputs 1-5 MOS), "audio" (default) for general audio.
STI/SII Measurement
Two methods are available for both speechTransmissionIndex and speechIntelligibilityIndex:
IR-based method (simpler — no alignment needed):
[ir, fs] = audioread("room_impulse_response.wav");
sti = speechTransmissionIndex(ir, fs);
sii = speechIntelligibilityIndex(ir, fs);Direct method (from test signals transmitted through the system):
fs = 48000;
reference = stipaExcitation(fs, Duration=15);
% Transmit reference through system, record as 'processed'
[processed, ~] = audioread("received_stipa.wav");
% IMPORTANT: Align signals before computing (see Signal Alignment)
processed = alignsignals(processed, reference);
sti = speechTransmissionIndex(processed, reference, fs);Ask the user:
Do they have an impulse response? → use IR method (simpler, no alignment needed)
Measuring live? → generate test signal, transmit, record, align, compute
STI or SII? STI for room/PA systems (IEC 60268-16); SII for hearing/communication (ANSI S3.5)
See references/sti-measurement.md for STI NV arguments, post-processing adjustment workflow (Annex M), test signal generation, and result interpretation. See references/sii-measurement.md for SII standard clause selection (5.1-5.3), BandImportanceFunction guidance, measurement positioning, and result interpretation.
SPL Measurement (Offline)
[audioIn, fs] = audioread("recording.wav");
spl = splMeter(SampleRate=fs, ...
Bandwidth="Full band", ...
FrequencyWeighting="A-weighting", ...
TimeWeighting="fast", ...
CalibrationFactor=2.3);
[Lt, Leq, Lpeak, Lmax] = spl(audioIn);
% For a single overall value, read the final row
fprintf("Leq: %.1f dB(A)\n", Leq(end));Valid Bandwidth values: "Full band" (overall level), "1 octave", "2/3 octave", "1/3 octave". There is no "broadband" option — use "Full band" for a single overall SPL value.
Output arity: All outputs (Lt, Leq, Lpeak, Lmax) have one row per input sample. For a 12-second file at 44.1 kHz, that is 539,648 rows. Never fprintf or disp the full output — it will hang. Instead:
Single overall value: read
Leq(end)(the final accumulated value)Time-interval readings: downsample to interval boundaries:
Leq(round(fs*T):round(fs*T):end, :)whereTis the desired interval in seconds
TimeInterval controls the integration window for Leq computation but does NOT reduce the number of output rows.
Do not manually compute 20*log10(rms(audioIn)/20e-6) — splMeter handles calibration, weighting, and time integration correctly per IEC 61672.
Multi-band (octave-band) SPL: Use splMeter with Bandwidth="1 octave" — do NOT use octaveFilterBank + manual dB conversion. Key properties for octave-band SPL:
[audioIn, fs] = audioread("recording.wav");
spl = splMeter(SampleRate=fs, ...
Bandwidth="1 octave", ...
FrequencyWeighting="Z-weighting", ...
TimeWeighting="fast", ...
FrequencyRange=[15 8000], ...
OctaveFilterOrder=8, ...
CalibrationFactor=2.3);
[Lt, Leq, Lpeak, Lmax] = spl(audioIn);
cf = getCenterFrequencies(spl);Critical gotchas for octave-band splMeter:
Property name is
OctaveFilterOrder(notFilterOrder).FilterOrderdoes not exist onsplMeter.FrequencyRangecompares against true center frequencies (fc = 1000 × 10^(3b/10)per IEC 61260), not nominal values. A band is included only if its true center falls within[lower, upper]. Bands below 1 kHz have true centers slightly above nominal (e.g., "63 Hz" = 63.10); bands above 1 kHz have true centers below nominal (e.g., "2 kHz" = 1995.26, "8 kHz" = 7943.28). Usefloor(true_center)for lower bounds andceil(true_center)for upper bounds. Common case "16 Hz to 8 kHz": use[15 8000]— the 16 Hz true center is 15.85 (so 15 ≤ 15.85 includes it) and 8 kHz true center is 7943 (so 8000 ≥ 7943 includes it). Do NOT use[16 8000]— this drops the 16 Hz band.Output is per-sample (see Output arity note above). Never print the full output. For time-interval readings, downsample:
Lt100ms = Lt(round(fs*0.1):round(fs*0.1):end, :);
See references/spl-measurement.md for weighting selection guidance (A/C/Z and fast/slow), SPL interpretation tables, occupational exposure limits, splMeter vs poctave equivalency, and common measurement scenarios.
Broadcast Loudness (EBU R 128)
[audioIn, fs] = audioread("broadcast_content.wav");
[loudness, loudnessRange] = integratedLoudness(audioIn, fs);
% Check compliance: target is -23 LUFS +/- 1 LU
isCompliant = abs(loudness - (-23)) <= 1;Use integratedLoudness for offline compliance checks. Use loudnessMeter for streaming/real-time monitoring (see matlab-process-streaming-audio).
RT60
[ir, fs] = audioread("room_ir.wav");
rtsummary = rt60(ir, fs, Bandwidth="1 octave");Ask the user:
What is the room type? (drives the target RT60)
Do they have an IR, or do they need to measure one?
T30 (standard) vs T20 (when noise floor limits dynamic range)?
See references/rt60-measurement.md for target RT60 values by space type, T20/T30/EDT interpretation, frequency-dependent analysis, and relationship to STI.
Tonality
[audioIn, fs] = audioread("machine_noise.wav");
[tnr, tnrFreq, isProminent] = acousticToneToNoiseRatio(audioIn, fs);
[pr, prFreq, isProminent] = acousticProminenceRatio(audioIn, fs);All outputs are empty (0×1) when no tonal components are detected. Check isempty(tnr) before indexing.
Standards-Compliant Filters (Custom Preprocessing)
The metric functions above perform standards-compliant filtering internally. Use standalone filter objects only for custom measurement workflows where no single metric function applies AND you do not need SPL output:
% A-weighting filter
wf = weightingFilter("A-weighting", fs);
weightedSignal = wf(audioIn);
% Octave-band filter bank (for waveform-level band decomposition only)
ofb = octaveFilterBank("1 octave", fs, ...
FrequencyRange=[31.5 16000], FilterOrder=8);
bandSignals = ofb(audioIn);If you need octave-band SPL levels, use splMeter with Bandwidth="1 octave" instead of octaveFilterBank + manual dB conversion. See the Multi-band SPL section above.
Signal Alignment
| Function | Internal alignment? | Action |
|---|---|---|
visqol | Yes | No action needed |
stoi | No | Align before calling |
speechTransmissionIndex | No | Align for direct method; IR method avoids issue |
speechIntelligibilityIndex | No | Align for direct method; IR method avoids issue |
For the direct (processed, reference, fs) method, always align signals:
processed = alignsignals(processed, reference);SII is more sensitive to misalignment than STI. At 50 ms delay: SII error ~0.016, STI negligible. At 200 ms: SII ~0.036, STI ~0.017. The IR-based (ir, fs) method avoids alignment issues entirely.
Common Mistakes
| Mistake | Why it fails | Correct approach |
|---|---|---|
Call pesq(reference, degraded, fs) | Function does not exist | visqol(degraded, reference, fs, Mode="speech") |
stoi(reference, processed, fs) | Wrong argument order | stoi(processed, reference, fs) — processed FIRST |
acousticFluctuationStrength(...) | Wrong function name | acousticFluctuation(audioIn, fs, calFactor) |
| Implement NC from scratch with hardcoded curves | Misses SIL, spectrum imbalance, rattle risk | noiseCriteria(audioIn, fs, CalibrationFactor=cf) |
20*log10(rms(x)/20e-6) for SPL | No weighting, no time integration, no calibration | splMeter with appropriate settings |
| Implement STI algorithm manually | ~100 lines, error-prone, misses NV options | speechTransmissionIndex(ir, fs) |
| Divide signal by calibration factor manually | Incorrect; factor is a multiplier, not a divisor | Pass as positional arg or CalibrationFactor=value |
| Skip alignment for direct STI/SII | Silent accuracy degradation | alignsignals(processed, reference) before calling |
Use acousticLoudness for broadcast loudness | Wrong standard (ISO 532 = sones, not LUFS) | integratedLoudness for EBU R 128 compliance |
string(rattleRisk) or fprintf("%s", specImbalance) | These are structs, not strings | Access .Summary field: rattleRisk.Summary |
specImbalance.Summary when NC is out of curve range | specImbalance degrades to char (not struct) when "Above NC-70" or below NC-15 | Guard: if isstruct(specImbalance), disp(specImbalance.Summary); end |
roomNoiseCriteria on recordings shorter than 15 s | ANSI/ASA S12.2-2019 requires ≥150 Lt samples at 100 ms intervals | Ensure recording is at least 15 seconds; use noiseCriteria for shorter clips |
round(NC) or arithmetic on NC/RC output | NC and RC are strings, not numbers | Use directly: fprintf("%s\n", NC) |
noiseCriteriaRecommendations() with no args | First argument (criteria name) is required | noiseCriteriaRecommendations("NC") |
loudness.OverallLoudness after acousticLoudness | Returns a scalar or vector, not a struct | Use directly: fprintf("%.1f sones\n", loudness) |
splMeter(..., FilterOrder=8) | Property does not exist on splMeter | Use OctaveFilterOrder=8 |
splMeter(..., FrequencyRange=[16 8000]) for 16 Hz–8 kHz | Drops 16 Hz band (true center is 15.85 Hz, which is below 16) | Use FrequencyRange=[15 8000] — use floor(true_center) for lower bound |
octaveFilterBank + 20*log10(rms(band)/pRef) for SPL | Manual, no time weighting, no calibration integration | Use splMeter with Bandwidth="1 octave" |
Treating splMeter output as a single value | All outputs have one row per input sample (e.g., 539k rows for 12s at 44.1 kHz) | Use Leq(end) for a single value, or downsample to interval boundaries |
Conventions
Always ask about the user's measurement goal before selecting a function
Always ask about calibration — recommend
calibrateMicrophonefor system-level accuracyDefault to
SoundField="free"for anechoic/outdoor,"diffuse"for reverberant roomsDefault to
Method="ISO 532-1"for loudness (Zwicker method, most common)Use IR-based methods for STI/SII when an impulse response is available (avoids alignment)
Pass
CalibrationFactorexplicitly rather than pre-scaling the signalFor noise compliance, prefer
roomCriteriafor HVAC andnoiseCriteriafor general background noise
Copyright 2026 The MathWorks, Inc.
Files
- ATTRIBUTION.mdAdded by AutoGineer1.1 KiB
- LICENSELicence file added by AutoGineer1.4 KiB
- SKILL.md22.7 KiB
- manifest.yaml444 B
- references/function-arguments.md7.3 KiB
- references/noise-compliance.md16.4 KiB
- references/psychoacoustic-metrics.md16.0 KiB
- references/rt60-measurement.md14.4 KiB
- references/sii-measurement.md16.9 KiB
- references/spl-measurement.md12.5 KiB
- references/sti-measurement.md14.0 KiB
references/noise-compliance.md
Noise Compliance Function Family
Intake Questions
Before writing code, ask the user about these topics to select the right function and parameters:
1. What is the noise source?
| Source | Implication |
|---|---|
| HVAC (fans, ducts, diffusers) | Use roomCriteria for spectral quality; noiseCriteria for compliance |
| Variable-speed drives or cycling equipment | Use roomNoiseCriteria — fluctuation penalty likely applies |
| General background (multiple sources) | Use noiseCriteria for a standard NC rating |
| Unknown / complaint investigation | Run all three methods and compare |
2. What is the space type?
Needed for selecting a design target. Common targets (from ANSI/ASA S12.2-2019 Tables C.1/C.2/C.3/D.2):
| Occupancy | NC/RNC Target | RC Target | A-weighted Target (dBA) |
|---|---|---|---|
| Concert hall / recording studio | 15–20 | RC 15–20 (N) | — |
| Courtroom / lecture hall | 25–30 | RC 25–30 (N) | 39–44 |
| Private office / conference room | 25–35 | RC 25–35 (N) | 44–48 |
| Classroom | 25–30 | RC 25–30 (N) | 35 |
| Open plan office | 35–45 | RC 35–45 (N) | 44–48 |
| Hospital patient room | 25–35 | RC 25–35 (N) | 35–39 |
| Restaurant / cafeteria | 40–45 | RC 40–45 (N) | 48–52 |
NC and RNC share the same recommendation targets — use RNC in place of NC when temporal variation is a concern. RC targets are from a separate table with different occupancy categories.
Use noiseCriteriaRecommendations("NC"), noiseCriteriaRecommendations("RC"), or noiseCriteriaRecommendations("A-weighted") for the full table with all occupancy types.
3. Is the noise steady or fluctuating?
Steady: NC or RC is sufficient
Fluctuating (surging, throbbing, cycling): Use
roomNoiseCriteria— it penalizes temporal variation that NC misses. RNC ≥ NC always (RNC is stricter). If RNC significantly exceeds NC, the fluctuation is the problem.Unsure: Record ≥15 s and run both
noiseCriteriaandroomNoiseCriteria; compare the ratings
4. What is the goal?
| Goal | Approach |
|---|---|
| Simple compliance check against spec | noiseCriteria → compare to target |
| Diagnose spectral problems in HVAC | roomCriteria → read QAI and classification |
| Investigate occupant complaints | Run all three; compare NC vs RNC for fluctuation penalty |
| Set design targets for new construction | noiseCriteriaRecommendations → specify in contract |
| Determine if noise affects speech | speechInterferenceLevel or SIL output from noiseCriteria |
5. Measurement conditions
Confirm with the user:
Calibration: Do they have a calibration factor? (See main skill for conversion from dB sensitivity)
Recording duration: ≥15 s recommended for
roomNoiseCriteria. The function will error on shorter recordings if surging or large random fluctuations are detected (the correction algorithm requires 150 Lt samples at 100 ms intervals, per clause 5.3.4). Shorter recordings pass if neither condition is detected.noiseCriteriaandroomCriteriahave no minimum duration requirement.Room conditions: HVAC systems should be operating at normal design conditions, room unoccupied but furnished, doors/windows closed
Microphone position: Ear height of typical occupant (seated ~1.2 m, standing ~1.5 m). Either measure at a specific position to be characterized, or sweep slowly throughout the space while remaining at least 0.6 m from any one surface, 1.2 m from the intersection of two surfaces, and 2.4 m from the intersection of three surfaces.
Note: these measurement conditions are for strict compliance with the standard. The functions accept any calibrated recording — the conditions affect the validity of the result, not the ability of the function to compute it.
Function Selection
| Function | Standard | Best For | Key Outputs |
|---|---|---|---|
noiseCriteria | ANSI/ASA S12.2-2019 (NC) | General background noise assessment | NC level, SIL, spectrum imbalance, rattle risk |
roomNoiseCriteria | ANSI/ASA S12.2-2019 (RNC) | Noise with audible temporal variation | RNC level, rattle risk |
roomCriteria | ANSI/ASA S12.2-2019 (RC Mark II) | HVAC system noise evaluation | RC level, LMF, QAI, rattle risk |
speechInterferenceLevel | ANSI/ASA S12.65-2006 | Quick speech interference check | SIL value (dB) |
noiseCriteriaCurves | ANSI/ASA S12.2-2019 | Look up NC curve SPL values | SPL values at octave bands for given NC level |
noiseCriteriaRecommendations | ANSI/ASA S12.2-2019 | Find target NC/RC/dBA for room type | Recommended range for specified room use |
Plotting: All noise compliance functions (noiseCriteria, roomCriteria, roomNoiseCriteria, noiseCriteriaCurves) produce a plot when called with no output arguments. Use this to visualize the measurement against reference curves. Encourage users to plot results for visual inspection.
Syntax and Outputs
noiseCriteria
Default choice for background noise assessment. Returns four outputs:
[NC, SIL, spectrumImbalance, rattleRisk] = noiseCriteria(audioIn, fs, ...
CalibrationFactor=calFactor);NC— NC level as string (e.g.,"NC-35")SIL— Speech interference level (average of 500/1k/2k/4k Hz bands)spectrumImbalance— Structure withSummary(string) andDetails(table showing deviation from reference NC curve per band)rattleRisk— Structure withSummary(string) andDetails(table showing measured levels vs. perceptibility thresholds)
Name-value arguments:
CalibrationFactor— Microphone calibration factor (default: 1)PressureReference— Reference pressure in Pa (default: 20e-6)ScreenSurging— Auto-detect surging in signal (default: true). Non-standard heuristic — per clause 5.3.2.1, surging should be detected by the user by listening or watching a meter for oscillations in low frequencies. Use this screening as a convenience, but inform users it is not a replacement for subjective assessment.ScreenLargeRandomFluctuations— Auto-detect fluctuations (default: true). Uses the algorithmic method from the standard — users can have confidence in this screening.
Can also accept pre-computed octave-band Leq values: noiseCriteria(Leq) where Leq is a 1-by-10 row vector (octave bands 16 Hz to 8 kHz).
roomCriteria
Preferred for HVAC noise specifically. The RC Mark II method adds a Quality Assessment Index (QAI) that characterizes the noise spectrum as neutral, rumbly, hissy, or vibratory:
[RC, LMF, QAI, rattleRisk] = roomCriteria(audioIn, fs, ...
CalibrationFactor=calFactor);RC— RC level as string (e.g.,"RC-32(N)"— the letter indicates spectrum quality)LMF— Mid-frequency average (arithmetic mean of 500/1k/2k Hz octave bands)QAI— Quality Assessment Index (lower is better; 0 = ideal neutral spectrum)rattleRisk— Structure with rattle risk assessment
The spectrum quality descriptor appended to RC:
(N)— Neutral: balanced spectrum, no corrections needed(R)— Rumble: excessive low-frequency energy(H)— Hiss: excessive high-frequency energy(RV)— Rumble with vibration risk
roomNoiseCriteria
Use when the noise has audible temporal variation (surging, random fluctuations). RNC is a stricter criterion than NC — it penalizes unsteady noise. Returns 2 outputs (not 4 like noiseCriteria):
[RNC, rattleRisk] = roomNoiseCriteria(audioIn, fs, ...
CalibrationFactor=calFactor);Minimum duration: ≥15 s recommended. The function errors on shorter recordings if surging or large random fluctuations are detected (the correction requires 150 Lt samples at 100 ms). Shorter recordings pass if neither condition is present.
Name-value arguments:
IsSurging—"auto-detect"(default),true, orfalse. The surging detection algorithm is a non-standard heuristic. Per clause 5.3.2.1, surging should be identified by the user by listening or watching a meter for oscillations in low frequencies.IsFluctuating—"auto-detect"(default),true, orfalse. This uses the algorithmic method from the standard.
Can also accept pre-computed measurements: roomNoiseCriteria(Leq, Lt) where Lt is an N-by-10 matrix of fast time-weighted SPL measurements (100 ms intervals, one row per time step). Lt must use fast time-weighting.
speechInterferenceLevel
Simplest metric for speech interference — returns just the SIL value:
SIL = speechInterferenceLevel(audioIn, fs, CalibrationFactor=calFactor);Supports time-varying output via TimeInterval:
SIL = speechInterferenceLevel(audioIn, fs, ...
CalibrationFactor=calFactor, TimeInterval=1);noiseCriteriaCurves
Look up SPL values for NC, RNC, or RC curves at standard octave-band center frequencies:
spl = noiseCriteriaCurves("NC", CurveID=35);
spl = noiseCriteriaCurves("RNC", CurveID=[25 30 35 40]);First argument is the criteria name: "NC", "RNC", or "RC" (required). CurveID selects specific curve levels.
The function can return values outside the published standard range (e.g., below NC-15 or above NC-70) for flexibility and implementation robustness. The standard only defines curves within its published range.
Calling with no output arguments plots the curve family. Set the Parent argument to place the plot axes in a desired Axes, UIAxes, or Panel — useful as a building block in larger visual metering displays and applications.
noiseCriteriaRecommendations
Look up recommended noise criteria levels by occupancy/room type:
rec = noiseCriteriaRecommendations("NC");
rec = noiseCriteriaRecommendations("RC", Occupancy="Private offices");
rec = noiseCriteriaRecommendations("A-weighted");First argument is the criteria name: "NC", "RNC", "RC", or "A-weighted" (required). Do NOT call with zero arguments or with a room-type string as the first argument.
Output Types
All noise compliance functions return strings and structs — not plain numerics for the rating outputs:
| Output | Type | Example |
|---|---|---|
NC | string | "NC-35" or "NC-56 (1000 Hz)" (band shown if one exceeds) |
RC | string | "RC-32(N)", "RC-47 (H)" (letter = spectrum quality: N/R/H/RV) |
RNC | string | "RNC-38" |
SIL, LMF, QAI | double | Scalar values in dB |
specImbalance | struct or char | .Summary (string) and .Details (table) — see note below |
rattleRisk | struct | .Summary (string) and .Details (table) |
To display struct outputs, access the .Summary field: fprintf("Rattle: %s\n", rattleRisk.Summary). Do NOT pass the struct directly to string() or fprintf %s.
Edge case: specImbalance degrades to a plain char string (not a struct) when NC exceeds the curve range (e.g., "Above NC-70") or falls below NC-15 — spectrum imbalance is undefined in both cases. Always guard before dot-indexing:
if isstruct(specImbalance)
fprintf("Imbalance: %s\n", specImbalance.Summary);
else
fprintf("Imbalance: %s\n", specImbalance);
endInput Flexibility
All noise compliance functions accept either:
Raw audio + sample rate:
func(audioIn, fs, CalibrationFactor=cf)— computes octave-band Leq internallyPre-computed octave-band Leq:
func(Leq)— a 1-by-10 vector (16 Hz to 8 kHz octave bands)
The raw-audio method is simpler and handles all filtering/integration internally. Use the Leq method when you have measurements from a physical SPL meter or from splMeter.
When providing pre-computed measurements: The SPL meter must use Z frequency-weighting (unweighted). This applies to all noise compliance functions (NC, RNC, RC) — octave-band filtering provides the frequency selectivity, so no additional weighting should be applied. For roomNoiseCriteria Lt input, also use fast time-weighting.
Interpreting Results
NC Rating Interpretation
The NC algorithm: compute SIL (average of 500/1k/2k/4k Hz bands) → select the NC curve corresponding to that SIL value → check if any measured bands exceed that curve → if so, apply the tangency method and append the tangent frequency.
Output formats:
"NC-35"— SIL-based rating; no band exceeds the SIL-selected curve"NC-42 (1000 Hz)"— Tangency method drove the rating; the noted band exceeds the SIL-selected NC curve. This indicates spectral imbalance at that frequency."Below NC-15"or"Above NC-70"— Outside the published curve range
The output is always an integer NC value. When the tangency-based NC exceeds the SIL-based NC by more than 3 dB, the spectrum has an imbalance. Check specImbalance.Details to see which bands deviate from the reference curve.
RC Mark II Classification — Engineering Actions
| Classification | Meaning | Typical Remediation |
|---|---|---|
(N) — Neutral | Balanced spectrum; ~5 dB/octave slope | Acceptable. No action needed. |
(H) — Hissy | Excessive high-frequency energy | Check diffuser throw velocities, duct lining condition, valve noise |
(R) — Rumbly | Excessive low-frequency energy | Check fan isolation mounts, duct breakout, flexible connectors |
(RV) — Rumbly-Vibratory | Severe low-frequency excess with vibration risk | Serious concern — address structure-borne transmission paths, verify inertia base isolation |
QAI (Quality Assessment Index):
QAI ≤ 5 dB: Acceptable spectral balance
QAI > 5 dB: Poor balance. The classification letter tells you which region dominates.
QAI = 0: Perfect match to the ideal RC contour (rare in practice)
RNC vs NC — Diagnosing Fluctuation
When RNC significantly exceeds NC for the same recording, the noise has temporal variation causing additional annoyance. The larger the difference, the more the temporal variation contributes to the overall noise problem.
Common causes of fluctuation: variable-frequency drives on fans, cycling compressors, duct resonances at low frequency, interaction between multiple HVAC units.
Speech Interference Level (SIL) Interpretation
SIL is the arithmetic average of octave-band Leq at 500, 1000, 2000, and 4000 Hz. Higher SIL values indicate greater difficulty communicating by speech. Compare against project specifications or use the STI/SII metrics for a more detailed speech intelligibility assessment.
Rattle Risk Interpretation
The rattleRisk output assesses whether low-frequency levels could excite lightweight building elements (ceiling tiles, light fixtures, ductwork panels):
No rattle risk: Levels are below perceptibility thresholds at 16 and 31.5 Hz
Moderate risk (Region B): Vibration moderately perceptible — may cause intermittent rattles
High risk (Region A): Vibration clearly perceptible — rattling of lightweight structures likely
Check rattleRisk.Details for the specific assessment per frequency band.
Troubleshooting
| Observation | Likely Cause | Action |
|---|---|---|
| NC seems fine but occupants complain | Noise fluctuates — NC averages away the annoyance | Run roomNoiseCriteria to quantify fluctuation penalty |
| NC exceeds target by 1–2 dB | One band drives tangency while SIL is within target | Check specImbalance.Details — treatment may be needed in one band only |
| RC shows "(RV)" | Severe low-frequency excess at 16 or 31.5 Hz | Do not attempt to mask with absorption — isolate the vibration source |
| RNC errors on short recording | Surging or fluctuation detected but recording under 15 s (correction needs 150 samples) | Re-record ≥15 s, or set IsSurging=false, IsFluctuating=false to bypass correction (result will not account for temporal variation) |
| NC/RC ratings differ significantly | They use different band ranges (NC: 63–8kHz, RC: 16–4kHz) and methods | Normal; RC captures low-frequency problems NC misses |
| Measurements vary widely by position | Room modes and proximity to sources | Report worst-case; measure at multiple positions or sweep per measurement conditions above |
| Bands below 63 Hz needed but instrument can't measure them | Type 2 meters often roll off below 63 Hz | Use Type 1 meter for RC/RNC (which include 16 and 31.5 Hz bands) |
| Background noise contaminates measurement | Source noise isn't >10 dB above ambient in all bands | Measure with source off, verify ≥10 dB separation. Apply background correction if 3–10 dB difference. |
Copyright 2026 The MathWorks, Inc.
Requirements and compatibility
Works with: Claude Code, Claude apps, OpenAI Codex, GitHub Copilot, Cursor, Gemini CLI, Kiro, OpenCode, Goose, Amp, Roo Code, JetBrains Junie, Factory Droid, Devin (ex-Windsurf), Mistral Vibe, OpenHands, Letta
“Works with” means the tool reads the open Agent Skills format; a skill written for one tool may use features others lack.
Security
No issues found by our static scan· No issues found
A static scan is not a guarantee. Skills are third-party content: review a skill before you let an agent use it.
Attribution and licence
- Created by
- MathWorks
- Publisher
- MathWorks (Official)
- Source
- matlab/matlab-agentic-toolkit · skills-catalog/signal-processing/matlab-evaluate-acoustic-metrics · commit 2a7f215
- Licence
- BSD 2-Clause License (redistribution allowed)
- LICENSE (added by AutoGineer from LICENSE.md)
- ATTRIBUTION.md (written by AutoGineer)
- Synced
AutoGineer is not affiliated with or endorsed by MathWorks.
Download ZIP
The ZIP holds the skill’s files, its licence files and an ATTRIBUTION.md. Download matlab-evaluate-acoustic-metrics.zip